NOAH
SUSTAINABILITYISINOURNATURE
Heat pumps foran energy-efficient everyday life anda betterworld
TICA
INTRODUCTION
Since the introduction of TlCA's first air-cooled heat pump at the end of the last century,we have been deeply committed to heat pump technology for nearly 30 years.With the continuousadvancementof refrigerants,TiCA has once again initiated innovations in heat pump systems.With the NOAH series,TICA wasone of the first manufacturers to optimally implement the environmentally friendly and highly efficient propertiesof the refrigerant R290,thereby expanding the potential of this refrigerant.
LOW-CARBON
One Ton Of \mathsf { C O } _ { 2 } Is Equivalent To:
Building A Sustainable Environment
Fora house witha living space of 180 square meters, afamilyofthreecanbeheatedwithconventional radiators:
Replacing a gas-fired boiler with a TICA heat pump will reduce your emissions by an average of 12261kg \mathsf { C O } _ { 2 } per year.
Replacing an oil-fired boiler with a TICA heat pump will reduce your emissions by an average of 17113 kg \mathsf { C O } _ { 2 } per year.
R290
Brings unbeatable benefits to our heat pumps:
TheR29O heatpumpfeaturesa SCOPofupto4.9, ensuring highenergy efficiencyand reduced running costs. Operating between - 2 5 ^ { \circ } \mathbb { C } and + 4 6 ^ { \circ } C , itprovides excellenthotwatercomfortandlegionellaprotection withouta backup heater.Witha GWPof just3,itoffers aneco-friendly heating solution,balancingminimal environmentalimpactwithoptimal performance.
公 8months householdelectricity 回 380L gasoline 4 100m2 mixed forest consumption BA 7500km bycar S 5000kmeconomicalflight 虹 27000km by train
What is GWP ?
GWP isa comparative value that indicates the greenhouse effect of a greenhouse gas to be released into the environment.The higher the value,theworse the impacton theclimate.
ExemplaryGWPsofsomerefrigerants:
Exemplarycalculation:
R410A 1.8 kg of R410Ax2088 GWP =3760 kg CO2
The value indicates the amount of \mathsf { C O } _ { 2 } which hasan equal globalwarming effect.
To calculate the \mathsf { C O } _ { 2 } impact of arefrigerant, the amount contained in the heat pump is multiplied by its GWP value.
13-hourflightfromLondontoKualaLumpur
R290 (NOAH)
0.6 kg of R290x3 GWP =1.8 kg CO2
15kmdrivebycar
點
R290
ECOfriendily Naturalrefigrant GWP3
TICA's cutting-edge heat pump technology using natural refrigerant (R290) is the best testimony to its future environmental commitment: The same heat pump, using R290, has only 0 . 0 5 % of the greenhouse effect of traditional R410A.
TICA SMART H@ME
Link To The Future
PREMIUMCOMFORT
QUIET OPERATION
Theuse of eficient,low-speed fansand advanced soundproofing measures ensures that thenoise fromthe outdoor unit isreduced tobelow 30 dBlA).Thisallows for flexible placement of the external unit without concerns,even indensely populated residentialareas,with noadverseeffectson you or yourneighbors.
Below 30dB(A)
Testcondition:Ambienttemp.(DB/ WB)7/6°C.Wateroutlettemp.55C
NOAH's noise reduction technology
Theenlarged fanallowsforlowerrotational speeds,reducingnoisewhilemaintaining efficiency.Combinedwith Panasonic'sDC brushlessmotor,itprovidesaquieter,more energy-efficientoperation.
The CFD-optimized, low-resistance air duct designensuresevenairflowdistribution, minimizingairresistanceanddelivering quieter,smootherairflow
Withtheintegration ofashock-absorbing padunderthecompressorandadual-layer chassis,noisereduction beginsat the source, leadingtosoftersoundoutputforamore comfortableacousticexperience.
Thecompressorisenclosedinmultiple layers ofsound-absorbingand insulatingmaterials Thisincludesenvironmentallyfriendlyflameretardantacousticinsulationandathreelayernoisereduction system,ensuringa significantlyquieteroperation.
TICA
SMARTCONTROL
TICA NOAH App- Comprehensive Smart Home Control
The TICA NOAH app offers a new level of control and comfort by making the management of the home automation solution easier.With TICA's innovative technology, the users have access to:
Remote management: Control your heat pump from anywhere in real time.
Programmable scheduling: Automate heating and cooling based on your routine.
Smart scene integration:
Create customized modes for various scenarios.
M
品
Energy monitoring:
Track power consumption and manage energy efficiency.
Fault detection and diagnostics: Get immediate alerts and run diagnostics remotely.
Multi-device management: Group and control multiple devices with ease.
& 自
Personalized settings: Adjust user preferences for a tailored experience.
Customer support: Firmwareupdates:
Access technical help anytime you need it.
Keep your system updated with the latest improvements.
TICA
SYSTEMSECURITY
R290 Refrigerant - Advanced Safety Solutions
Recognizing thesafetydifferencesbetween R290and refrigerants like R32 or R410A,we have introduced five progressive safety protocols.These measures are specifically designed to minimize accident risks andensuresecuresystemoperation.
TICA NOAH Monobloc Heat Pump - Enhanced Safety Innovations
1 SealedElectricControlBox(IP55]
Featuringa fireproof and explosion-proof control box designed forA3refrigerants,the fullysealedunit protects electrical components from refrigerant leaks,ensuring enhancedoperationalsafety.
2 Explosion-ProofElectricalSystems
Integrated explosion-proof electricalcomponentseliminate potential ignition sources,safeguarding the system.
Reduced RefrigerantVolume
The φ5 tubing lowers the refrigerant volume,enhancing the overallsafetyprofileofthesystem.
4 ComprehensiveDesignwithExhaustValve
The all-in-one design with an integrated exhaust valve ensures refrigerant stays outside the building,contributing toasafer indoorenvironment.
5 AdvancedLeakDetectionSystems
Double detection via sensors and advanced algorithms ensures thatrefrigerant leaksare immediately identified, optimizing operational safety.
NOAH
ABOUTPRODUCTION
MESFull Life Cycle Management System
Starting from the raw materials,the production of all unitsis controlled by the MES system,making the entire production process more digital and standardized.Until the NOAH heat pump meets you,every process is traceable.
Auto.detectionofwaterpressure
Digitalmonitoringofvacuumpumping
TICA
CERTIFICATIONS
| Model | TUCA040KHLB | TUCA060KHLB | TUCA080KHLB | TUCA100KHLB | TUCA120KHLB | TUCA140KHLB | TUCA160KHLB | ||
| Powersupply | 220~240V-50Hz | 380~415V-3N-50Hz | |||||||
| Heating(A7W35] | Capacity | W | 4500 | 6200 | 8400 | 10000 | 12000 | 14000 | 15000 |
| COP | / | 5.42 | 5.25 | 5.15 | 5.05 | 5.15 | 5.05 | 5.00 | |
| Capacity | W | 4500 | 6000 | 8000 | 10000 | 12000 | 14000 | 15000 | |
| Heating(A7W45) | COP | / | 4.20 | 4.05 | 3.90 | 3.65 | 3.90 | 3.75 | 3.60 |
| Capacity | W | 4600 | 6200 | 8000 | 9500 | 12000 | 14000 | 15000 | |
| COP | / | 3.40 | 3.35 | 3.30 | 3.20 | 3.30 | 3.20 | 3.10 | |
| Heating(A2W35] | Capacity | W | 4400 | 5600 | 7100 | 8200 | 11000 | 12000 | 13000 |
| COP | / | 4.10 | 3.90 | 3.85 | 3.65 | 3.75 | 3.65 | 3.50 | |
| Heating(A-7W35) | Capacity | W | 4500 | 5800 | 7200 | 8000 | 10500 | 11500 | 12800 |
| COP | / | 3.20 | 2.95 | 3.10 | 2.85 | 3.10 | 3.00 | 2.85 | |
| Cooling[A35W18] | Capacity | W | 4300 | 5600 | 7000 | 8600 | 12000 | 140000 | 16000 |
| EER | / | 5.20 | 4.70 | 4.95 | 4.50 | 4.60 | 4.30 | 4.00 | |
| Cooling(A35W7] | Capacity | W | 4100 | 5600 | 6800 | 7600 | 12000 | 13500 | 14500 |
| EER | / | 3.42 | 3.01 | 3.21 | 3.04 | 3.05 | 2.90 | 2.75 | |
| SCOP | Averageclimate,W35 | / | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ |
| Average climate,W55 | / | A+++ | A+++ | A+++ | A+++ | A++ | A++ | A++ | |
| Net weight | kg | 117 | 117 | 132 | 132 | 168 | 168 | 168 | |
| Gross weight | kg | 137 | 137 | 152 | 152 | 192 | 192 | 192 | |
| Net dimension(W*D*H) | mm | 110O×458x945 | 1100×458×945 | 110O×458×945 | 1100x458×945 | 110Ox458x1520 | 110Ox458x1520 | 110Ox458x1520 | |
| Packing dimension(W*D*H) | mm | 118Ox60Ox1115 | 118O×60Ox1115 | 118Ox6O0x115 | 118O×60Ox1115 | 1180×60Ox1705 | 1180×600x1705 | 1180×60Ox1705 | |
| Erpsound power level | dB | 55 | 55.5 | 56 | 57.5 | 60 | 61 | 62 | |
| R290/3 | R290/3 | R290/3 | R290/3 | ||||||
| Type/SWP | /灯 | R290/3 | R290/3 | R290/3 | |||||
| Operating ambient | Cooling | ℃ | 5~46 | 5~46 | 5~46 | 5~46 | 5~46 | 5~46 | 5~46 |
| Heating | ℃ | -25-43 | -25-43 | -25-43 | -25~43 | -25~43 | -25~43 | -25-43 | |
| DHW | ℃ | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | |
| ℃℃ | |||||||||
| Water setting | Coling | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | |