TXSENSER PRODUCTMANUAL
Leaders in Optical Sensing for Gas Detection
Preciseand Efficient
Safeand Reliable
CONTENTS
Company Profile 03
Technology Advantage 07
Product Introduction
GasSafetyMonitoringSolution
Industrial Gas Safety Monitoring System 09
Natural GasSafety Monitoring System 11
Universal GasDetection
GB8 Fixed Gas Detector GB8 13
XA8 Open Path Gas Detector XA8 15
XH8 Open Path Gas Detector XH8 17
XG8 Open Path Gas Detector XG8 19
AA6 Gas Alarm Controller AA6 21
Gas Alarm Controller A-711-B01 23
XB8Laser Gas Remote SensingDetector XB8 25
XD8Laser Gas Remote Sensing Detector XD8 27
BA8Portable Gas Detector BA8 29
Portable Multi-Gas Detector BB9 31
CoalMineGasDetection
Coal Mine Laser Gas Detector GJJ100B-INTL 33
MiningLaserMethane Power Failure Device DJJ100/127-INTL 35
Coal Mine PortableLaser GasDetectorBA8 37
Detector Intelligent Charging Cabinet CLF-50WG-INTL 39
Coal Mine PortableLaserGasDetector BC8 41
Coal Mine Laser Methane Remote Sensing Detector XB8 43
Optional Components
Gas Sampling Pump TX1000-INTL 45
Optical Reflector TX3000-INTL 47
Calibration GasBoxTX4000-INTL 48
ABOUTCOMPANY
HXTX Sensing Technology (Dalian) Co.,Ltd.,awholly-owned subsidiary ofHXTX Group,was established in March 2019 with a registered capital of136 millionRMB.The company is committed to the research and development of optical detection technology,so that life away from the harm of harmful gases,vision to become the optical technology leader in the field of gas detection.
HONOR QUALIFICATION
·High Tech Enterprises
·Intelligent Factory in Liaoning Province
·Liaoning Province Eagle Enterprise
·Dalian No Waste Factory
· Dalian Green Manufacturing Factory
·Liaoning Province Green Manufacturing Factory
·Dalian Technology-based Small and Medium-sized Enterprises
·Innovative Small and Medium Sized Enterprises in Liaoning Province
·Liaoning Province's Technology-based Small and Medium-sized
Enterprises
·Liaoning Province Advanced-Level Intelligent Factory
·AAAlevel IntegratedManagementSystem
·LiaoningProvince'specialized,Refined,Unique,and Innovative
Small and Medium-sized Enterprises
·National Enterprise ofProduct/Service Quality&Integrity Commit
ment
·Dalian Demonstration Enterprise forCollaborative Transformation
and Development of Industrialization and Informatization
·Liaoning Province's Pilot Unit for Implementing The Integrated
Management System of Informatization and Industrialization
·Dalian Digital Green Collaborative Transformation Developmen
Demonstration Enterprise
·The 4th Safety Science and Technology Progress Award of China
Association of Work Safety
Expert in optical sensor specialize in gas detection
The main business includes the development and production of ga detection instruments based on laser technology,industrial gas safet monitoring system and so on.The products are mainly used in ga measurement and safety monitoring in coal mine,petroleum an petrochemical, natural gas and environmental protection fields,ani provide technical support and service of sensing layer for smart safet. supervision, smart city and smart mine.
The company has 10o,0oo ultra-clean production workshop and th first fully automatic laser gas sensor production line in China,witl independent research and development and mass production capacit of laser sensing products,master the manufacturing process ani technology of laserand othercore devices.
AAAEnterprise,CreditRatingCertified bySGS, TUV Rheinland, etc. National patents|46,Invention patent|9 R&D achievements recognized as "Internationally Leading" by China Association ofWork Safety
Cutting Edge Manufacturing Leading Industry Standards
·Build a highly automated and digital intelligent factory based on Industry 4.0 standards,achieving comprehensive connectivity from the equipment layer to the informationlayer. ·With the help of MES system,we can achieve full traceability from raw material storage,production process control to finished product delivery, ensuring transparency and controllability of quality and process.
Registered capital 136 MillionCNY
Factory area occupied 10,000
Automated Assembly Center
The25oo+squaremetermodernassemblycenterhasfully deployed MES intelligent production management system, achieving highautomationat the equipmentlevel and seamless integrationattheinformationlevel.Notonlyhasitachieved automation control, visual monitoring, and digital managementof the entire production andassemblyprocessofcore products, but it has also significantly improved production efficiency and product quality, ensuring that every product leavingthefactoryhasexcellentperformanceandreliability.
Production workshop actual shooting
1 Created China's inaugural fully-automated laser gas sensor production line.
2 Master the production and manufacturing process and technology of core optical devices.
3 Independently researches developsand mass-produces laser-based gas detection products.
X
Tunable Diode Laser Absorption Spectroscopy
Technology Advantage
| Gategory | Laser | NDIR | Catalytic/ Electrochemical | Semiconductor |
| Measurement Precision | √ | √ | ||
| Moisture Resistance | × | × | × | |
| Sensitivity& Range | × | √ | ||
| Remote Detection Capability | √ | × | ||
| Intrinsically Safe& EMC | √ | × | × | |
| Gas Mono-selectivity | × | × | ||
| Response Time | √ | √ | × | |
| Operating Life | √ | × | √ |
Product Type
Industrial Gas Safety Monitoring System
SystemIntroduction
TheIGMSeloee enablest maagtell ceutical,food,tobaccoandmanyotherindustrialfields,theIGSMsystemtopologydiagramisshownbelow.
ApplicationSite
Combined with the on-site pain point needs and related technical analysis, the project teamadopted laser gas detection technologyas the design basis andformulatedtargetedsolutions,asfollows:
OUsing the reflection characteristic of laser,the special position can be monitored at a long distance without contact
Laser-sensingrisks,intelligently guardingindustrial safety.
②The IGSM system platform is used for centralized management of data visualization and upgradingmanagement methods
Natural Gas Safety Monitoring System
System Introduction
TheNGdetao istheoretoeodo gasfpeieddlace Systemcan realize real-time monitoring and early warning of natural gas leakage disasters and realize 7 { x } 2 4 hours unattended,which can not only improve the ispctio on-sitesofosltiesesao the system topology.
SystemCharacteristic
\bullet The use of advanced laser gas detection technology,7x24 hours for large area coverage monitoring.
{ ±b { θ } } Set explosion-proof video and gas detection function as one,360o Rotating line-type optical beam gas detector No dead Angle monitoring No dead Angle monitoring.
±b { \Theta } Fixed point automatic cruise can be set to achieve unattended.
Theplatform software can realize customized intelligent AI functions such as perimeter and helmet recognition. Highly selective to methane gas,not affected by other gases and weather,lowfalsealarmrate. \bullet Support solar power supply, wireless communication function,adapt to various special scenarios.
ApplicationScenario
Digital-Intelligent Platform
GB8 Fixed Gas Detector GB8
ApplicationFeatures
Industrial24/7 Monitoring
·TDLAS-based CH4 detection (full-scale coverage) · - 4 0 ^ { \circ } { C } to + 7 0 ^ { \circ } { C } outdoor-rated operation
Zero-Maintenance Operation
·Lifetime calibration-free with embedded diagnostics ·Sensor poisoning immunity|Humid/dust-resistant performance
SmartIntegration
·ModbusRTU&4-20mA/RS485DCS-ready ·IR remote setup (no manual adjustments in hazardous zones)
Intrinsic Safety
·High Safety Level Certification,IP66High Protection Rating ·Anti-corrosion alloy for oil/gas environments
Specification
SamplingMethod Passive Diffusion
Measuring Range 0-100%LEL
Accuracy 0-60%LEL:±3%FS 60-100%LEL:±5%F.S
Resolution 1%LEL
Response Time (T90) ≤25s
Display Type 7-segment LED
AlarmSoundLevel >80dB@1m
Environmental Parameters
·Operating Temperature IndoorType:-10-55℃ Outdoor Type:-40-70℃
·Storage Temperature -40-70℃
·Operating Humidity ≤98%
·Operating Pressure 80kPa-116kPa
Power Specifications
·Input Voltage 12-24VDC
·Power Consumption <3W
Communication Specifications
·Communication Interface 4-20mA(Default)orRS485/LoRa
·Communication Protocol ModbusRTU
Mechanical Construction
·Shell Material Aluminium Alloy
·Ingress Protection IP66
·Weight 2.1kg
EquipmentFunctions
LaserMethane Detection(Custom gases) Over-LimitAlarm
AreasofApplication
Oil&GasProduction
·Real-timeCH4 monitoringondrilling platforms
·Frackingzonecombustible gasearlywarning
PipelineIntegrity
·24/7leakdetectionat valve stations
·Subseapipelineend terminal protection
StorageFacilities
·LNGtankcontainment arearisk assessment
·Tank truck loading zone gas dispersion monitoring
IndustrialProcesses
·Chemical reactorCH4 accumulation alerts
·Biogas upgrading plant concentration control
Urban Infrastructure
·Utilitytunnel gasmonitoringnetworks
·Landfill gascollectionsafetysystems
Certifications
Explosion Protection
·ChinaEx ·ATEX
-ExdbibIICT6Gb -ExI2GExdIICT6Gb
-ExibtbIIICT80℃Db
SelectableGasesforDetection
Fixed Gas Detection
XA8 Open Path Gas Detector XA8
CH4 Laser
ApplicationFeatures
Point&PathFusion,Dual Verification
·Combines diffusion and remote sensing for wide coverage and precise quantification ·Dual-mode design detects both large-scale dispersion and minor leaks
IndependentPod,FlexibleAlignment
·Remotely adjustable module for precise targeting without moving main unit · Upgraded structure enables reliable one-person on-site setup
Long-Range Tracking,Second-Level Response
· 6 0 { m } non-contact optical path with ^ { < 1 } s response for linked control ·Laser technology resists interference,filters moisture/dust, zero false alarms
Pre-Calibrated,Plug-and-Play
·Factory pre-calibrated with standard Modbus/4-20mA interfaces ·Compact, maintenance-free design fits confined spaces
Specification
SamplingMethod Open Path+Passive Diffusion
PathLengths 60m
Measuring Range 0-100,000 ppm·m (Line Type) 0-100%LEL (Point Type)
Accuracy ±20%@StandardReflectiveSurface (Line Type) 0-60%LEL:±3%F.S (Point Type) 60-100%LEL:±5%F.S (Point Type)
Response Time(T90) <1s (Line Type) ≤25s (Point Type)
Display Type ColorLCD
EnvironmentalParameters
·Operating Temperature -10-50℃
·Storage Temperature -40-60℃C
·Operating Humidity ≤98%
·Operating Pressure 80kPa-116kPa
Power Specifications
·InputVoltage 12-24VDC
·Power Consumption ≤6W
Communication Specifications
·Communication Interface 4-20mA(Default)orRS485/LoRa
·Communication Protocol ModbusRTU
Safety Classification
·Detection Beam CLASSI
·Alignment Beam CLASS IIIR
MechaLaser
·ShellMaterial Aluminum alloy
·Ingress Protection IP68
·Weight 2.2kg
EquipmentFunctions
Dual-modePoint/LineMonitoring(GasCustomizable)
RapidLeakDetectionandAlarm
FlexibleAdjustableMonitoringDirection
Hidden-bayMagneticPenSystem
AreasofApplication
NaturalGasStations&ValveRooms
·High-precision point quantitative monitoring for complex valve rooms
·Utilizes open optical path for long-distance monitoringacross station areas
LNGStorageTankAreas&PumpHouses
·Precision monitoring of key leakage sources such as compressors and
pumpunits
·Wide optical path coveragefor tank perimetersand loading/unloading platforms
Oil&GasFieldWellheadStations
·Long-distanceoptical path for integrated monitoringof multiplewellheads with single-device control
·Efficientlyaddressesleakagelocalizationandcoveragechallengesindense
well clusters
High-ValueEquipmentProtection
·Dual monitoring for core high-value equipment like gas turbines and booster compressors
·Close-range concentration measurement combined with long-range diffusion trackingandearlywarning
Certifications
ExplosionProtection ·China Ex -ExdbibIICT6Gb -ExtdibIICT80℃Db
Open Path Gas Detection
ProductDimensions
Unit:mm
XH8 Open Path Gas Detector XH8
CH4 Laser
ApplicationFeatures
Long-Range Detection
·TDLAS Non-Contact Monitoring, 5 0 0 { m } Reflection Path Full Coverage ·Instant ls alarm triggering with Front-Back Mirrored Display System
Industrial Protection ·IP68& 304/316L stainless steel ·ModbusRTUcascade alarmnetworks
HarshEnvironment
·AGC anti-fouling: Rain/snow/dust compensation ·Signal penetration through heat haze/smoke
Specification
EquipmentFunctions
SamplingMethod PathLengths
Open Path
120m(Diffuse Reflection)
500m (with Retroreflector)
0-100,000 ppm·m
±20%@Standard reflectivesurface
<1s
ColorLCD
MeasuringRange
Accuracy
Response Time (T90)
Display Type
Environmental Parameters
·Operating Temperature
·Storage Temperature
·Operating Humidity
·Operating Pressure
PowerSpecifications
·Input Voltage
·Power Consumption
CommunicationSpecification
·CommunicationInterface
·Communication Protocol
-20-60°C -40-60°℃ ≤98% 80kPa-116kPa
100-240VAC,50/60Hz ≤15W
RS485(Default)orFiberor Ethernet ModbusRTU(RS485) ModbusTCP(Fiber/Ethernet)
Relay Characteristics ·ContactForm
·ContactRatedLoad
SPST-NO
(SinglePoleSingleThrow,NormallyOpen)
1A@DC30V
0.15A@AC220V
LaserSafetyClassification
·Detection Beam CLASS I
·Alignment Beam CLASS IIIR
MechanicalConstruction
·ShellMaterial 304StainlessSteel (Customizable316LStainlessSteel)
·Ingress Protection IP68
·Weight 13kg
Non-contact Laser Methane Long-range Monitoring(Custom Gases)
RelayOutputFunction
Front-BackMirroredDisplaySystem
FieldDataDisplayandAlarmFunction
AreasofApplication
EnergyFacilities
·LNG tank 500m-levelboundary alerts ·Gasstorage linear pathmonitoring UrbanGas
·Pipeline crossing directional sentry ·Citygatestationoverflowalarms
IndustrialSafety
·Steelplantcokegaslinear tracking ·Landfillbiogasmigrationmonitoring EmergencyResponse
·Oilfield perimeter long-rangealerts ·Hazard containment directional setup
Certifications
ExplosionProtection ·China Ex -ExdbIICT6Gb
Selectable Gases forDetection
| Laser | CH4 | NH3 | C2H2 | Co | CO2 | HCL | O² |
Open Path Gas Detection
ProductDimensions
Unit:mm
XG8 Open Path Gas Detector XG8
ApplicationFeatures
Intelligent Scanning
RuggedDeployment
·Rain/fog-resistant TDLAS detection ·Pan-tilt trajectory tracking& leak pinpointing
·Pre-calibrated& solar-ready ·304/316L Stainless steel for chemical resistance
Dual Explosion Proof
·Exd& Ex tD certifications for gas/dust zones ·IP68 protection for harsh environments
EquipmentFunctions
SamplingMethod PathLengths
MeasuringRange Accuracy Response Time (T90) CameraParameter
MaximumCruisePoints
EnvironmentalParameters
·Operating Temperature
·Storage Temperature
·Operating Humidity
·Operating Pressure
Power Specifications
·InputVoltage
·Power Consumption
·Start-up Current
CommunicationSpecifications
·CommunicationInterface
·CommunicationProtocol
LaserSafetyClassification
·Detection Beam
·AlignmentBeam
MotionCharacteristics
·Horizontal Range
·Horizontal Rotation Speed
·VerticalRange
·Vertical Rotation Speed
Mechanical Construction
·ShellMaterial
·Ingress Protection
·Weight
Open Path
120m (Diffuse Reflection)
500m(with Retroreflector)
0-100,000 ppmm
±20%@Standard reflective surface
<0.1s
1/2.8"CMOs,2 million pixels,
1920×1080,25X optical zoom
255
-40-60℃C
-40-60℃
≤95%
80kPa-110kPa
100-240VAC,50/60Hz
≤75W
<1.5A
RS485|CH1 (Concentration) RS485|CH2(PTZControl) ETH10/100/1000M(Video) ModbusRTU @CH1 PELCO-D/P@CH2 TCP/IP@ETH
CLASSI CLASSIIIR
360°ContinuousRotation
0.1°-40/SSmooth Variable SpeedRotation -90°-+90°
0.1-30/SSmoothVariableSpeedRotation
304 Stainless Steel
(Customizable316LStainlessSteel)
IP68
35kg
Non-contactLaserMethane PTZ Scanning Monitoring(Custom gases)
HDCamerawith InstantPhotoCapture
Dual-WiperAuto-CleaningSystem
24/7AutonomousOperationwithPCsoftware
AreasofApplication
Oil&Gas
·Wellhead monitoring&perimeterscanning
·Compressor plant gas dynamic tracking
Chemical Storage
·Tank farm emission boundary alerts
·Loading zone dispersion path analysis
UrbanGas
·Pipelineconcentration visualization
·LNG station explosion-proof zone alarms
IndustrialSafety
·Refineryperimeterprotection systems
·Powerplantcombustiblegasdetection
MobileSolutions
·Fleet-based rapid source identification
·24/7emergencydeploymentsupport
Certifications
Explosion Protection
·China Ex -ExdbIICT6Gb -ExtbIIICT80CDb
SafetyIntegrityCertification
·ATEX -II2GExdbIICT6Gb -II2DExtbIICT80CDb
| Laser | CH4 | NH3 | C2H2 | Co | CO2 | HCL | O2 |
Open Path Gas Detection
Unit:mm
AA6 Gas Alarm Controller AA6
ApplicationFeatures
Multi-Point Smart Monitoring
FlexibleNetwork&Cloud
·Up to 240 detectors,wide area coverage * Multi-sensor support, complex scenarios
·4G/Ethernet,MQTT,data to cloud * Optional LoRa, wireless deploy, cost-saving
Industrial-Grade Reliability
Easy&EfficientMaintenance
· { \displaystyle - 2 0 ^ { \circ } C { ~ } 7 0 ^ { \circ } C } wide temp,robust outdoors ·IP65 protection,dust & water proof,long life
* ColorLCD,audio-visual alarms,fast response * SD card log,data trace,easyanalysis
EquipmentFunctions
DetectorCapacity UnitTypes MaximumRange Display Type AlarmType InputChannels (Single Optional)
SwitchOutput
Data Output
RelayCharacteristics ·ContactForm ·ContactRatedLoad Storage Specifications ·StorageCapacity
240Units
%LEL;%LEL·m; %VOL;%VOL·m; ppm; ppmm
200%LEL;100%VOL;999,999ppm
LCDColor TouchScreen
Audibleand Visual Alarm
4-20mA|16Channels
RS485ModbusRTU|1Channel
LoRaWireless|1Channel
Two-stageAlarmRelay|2Channels
FaultRelay|1Channel
ShieldingRelay|1Channel
4GNetworkCommunication(OptionalNB-IoT),MQTTProtoco
10/100/10ooMEthernetTCP/IP,ModbusRTUProtocol
SPST-NO(SinglePoleSingleThrow,NormallyOpen) 5.0A@AC220V
HistoryRecords>1,000,000 AlarmDataRecords>200,000 Power-offRecords >10,000 OperationRecords>10,000 FaultRecords>10,000 Shielding Records >10,000 ·StorageMethod SD Card(Removable) EnvironmentalParameters ·Operating Temperature -20-70℃ ·Storage Temperature -40-70℃ ·Operating Humidity ≤98%RH ·OperatingAir Pressure 80kPa-116kPa Power Specifications ·Input Voltage MainPower:80-305VAC,50/60Hz BackupPower:12V4.5AhLead-AcidBattery,Runtime≥2h ·Power Consumption ≤150W(FullLoad) ·Power Output 24VDC,6A(Main Power Supply) MechanicalConstruction ·ShellMaterial Galvanized Steel Sheet ·IngressProtection IP65 ·Weight 5.0kg
Multi-channel Data Acquisitionand Storage MultipleAlarmSignalOutputs FlexibleIntegrationofMulti-typeDetectors WirelessData Transmission Function IntelligentSelf-checkingandFaultDiagnosis UnifiedUserPermissionManagement
AreasofApplication
SmartChemicalParkSafety
·Plantareagrid monitoring,productionsafety
·Corridors&warehouses,leakearlywarning
MunicipalGasRefinedMgmt
·Pipelinestationmonitoring,quick incidentresponse
·Underground pipes,safety statusalerts
Warehouse&LogisticsSafety
·Hazardousstoragemonitoring,over-limitalarm
·Coldchainlogistics,refrigerantleakdetection
Environmental&ExhaustMonitoring
·Industrial exhaust,online continuous monitoring
·Air quality grid, pollutionsource tracking
OtherIndustrial Safety
·Spray/weldingshops,gassafetymonitoring
·Pharma/electronics,VOCsgasdetection
Gas Alarm Controller A-711-B01
ApplicationFeatures
CompactStandaloneMonitor-Efficient&Economical Multi-InterfaceCompatibility&FlexibleConfiguration
·Designed for small, independent applications,supports 8-channel signal input.
* * High cost-effectiveness meets budget-sensitive monitoring needs.
·Supports 4-20 mA and RS485 Modbus RTUwired communica tion. ·Optional LoRa wireless for flexible site wiring.
Reliable Performance&Traceable Safety
IntuitiveColorDisplay& User-FriendlyOperation
·Stores up to 4Ooo alarm and fault records for clear event tracking. * Integrated backup power supports { > } 2 { h } outage monitoring.
·3.5-inch TFTcolorLCDclearlypresentsall 8-channel data. ·Audible and visual alarms activate simultaneously for prompt alerting.
Specification
EquipmentFunctions
Detector Capacity Unit Types Maximum Range Display Type Alarm Type InputChannels (Single Optional)
Switch Output
DataOutput
RelayCharacteristics ContactForm ContactRatedLoad Storage Specifications StorageCapacity
StorageMethod
EnvironmentalParameter
OperatingTemperature
StorageTemperature
Operating Humidity
Operating Pressure
PowerSpecifications
InputVoltage
Power Consumption
PowerOutput
MechanicalConstruction
ShellMaterial
Ingress Protection
Weight
8Unit
%LEL;%LELm; %VOL; %VOL·m; ppm; ppm·m
100%LEL;100%VOL;999,999ppm
3.5-inch TFTColorLCDScreen
AudibleandVisualAlarm
4-20mA|8Channels
RS485|1Channels
LoRa|1Channels
AlarmRelay|2Channels
FaultRelay|1Channel
RS485|1Channels (Default Modbus RTU protocol
supports wireless and protocol customization.)
SPST-NO(SinglePoleSingleThrow,Normally 5.0A@AC220V
AlarmDataRecords>4,000
FaultRecords>4,000
Internal Storage (Non-exportable)
-20-70℃C
-40-70℃
≤98%
80kPa-116kPa
80-305VAC,50/60Hz/MainPower:80-305VAC
16.8V3000mAhLithiumBattery,Runtime≥2h
≤50W(FullLoad)
24VDC/2A (MainPowerSupply)
Galvanized Steel Sheet
IP54
2.75kg
Multi-Channel Signal Acquisition&Display Over-LimitAudio-VisualAlarms IntelligentOn-SiteDataLogging SupportsField-Triggered Outputs
AreasofApplication
SmallIndustrialPlants
·Productionareas,equipment rooms,andwarehouseswith limitedmonitoringpoints
IndependentCommercial&IndustrialSites
·Small boiler rooms,pumpstations,independent gas storagefacilities,laboratories
·Kitchenareasinsmallbusinessesandrestaurants
MunicipalGasLocalManagement
·Small gas pressure regulation stationsand pipeline terminal monitoring points
RapidDeploymentScenarios
·Suitableforsmallindependentsystemswithalimited number of monitoring points
Gas Detection Controller
XB8Laser Gas Remote Sensing Detector XB8
ApplicationFeatures
Remote Detection
·Penetrates glass/flame via laser telemetry ·Industry-leading ppm sensitivity& detection limits
IndustrialReliability
·IP65 housing& ergonomic design for harsh O&G sites · 24/7 runtime with instant-charge docking
Specification
SamplingMethod OpenPath
PathLengths 60m
Measuring Range 0-100,000 ppmm
Accuracy Truevalue±20%@Standardreflective surface
Response Time (T90) <0.1s
Display Type ColorLCD
EnvironmentalParameters
·Operating Temperature -10-50℃
·Storage Temperature -40-60℃
·Operating Humidity ≤98%
·Operating Pressure 80kPa-116kPa
Power Specifications
·Endurance Normal operation >8H Full load operation>4H (Continuous soundand lightalarm)
·ChargingMethod ChargingDock
·Intemal Battery Built-inLithiumManganateBattery
LaserSafetyClassification
·Detection Beam CLASSI
·Alignment Beam CLASSIIIR
Mechanical Construction
·Shell Material ABS+PC
·Ingress Protection IP65
·Weight 420g
LeakLocalization
·Green laser guidance with real-time tracking * * Explosion-proof certified & precalibrated for safety
EquipmentFunctions
HandheldMethaneLeakLocator(Customgases) Real-timeLeakSourceLocalizationandAlarm Tri-modeAlarms(Sound/Light/Vibration)
AreasofApplication
EnergyInfrastructure
·Remote leak screening for refinery pipelines/LNG tanks
·Real-timeseal monitoringatwellheads
UrbanGasSystems
·Non-invasiveleakdetectioninburieddistributionnetworks
·Failure localizationat gas pressure stations
IndustrialSafety
·Pressurizedleak sourcetracinginchemical plants
·Pre-entryhazardscanningforconfinedspaces
Certifications
Explosion Protection
·ChinaEx
-ExibIICT4Gb
·ATEX
-ExII2GExibICT4Gb
Portable Gas Detection
| Laser | CH4 | NH3 | C2H2 | Co | CO2 | HCL |
ProductDimensions
Unit:mm
XD8Laser Gas Remote Sensing Detector XD8
ApplicationFeatures
ExtremelyLightweight&ExceptionalValue
· Ultra-compact, pocket-sized for easy carrying ·Cost-effective for universal personal safety wear
IntegratedLight&Detection,Multi-Functional
·Built-in bright flashlight forcabinets,basements,and dark spaces ·Sliding cover toggles light/detection mode for efficient inspections
Dual-Power Convenience,Easy Charging
·Removable rechargeable battery eliminates power anxiety ·Integrated Type-C direct charging for flexible power needs
PrecisionShort-Range&FastResponse
·15-meter detection range optimized for close-up inspection ·Tripod mount included for extended fixed-point monitoring
Specification
SamplingMethod Open Path
PathLengths 15m
MeasuringRange 0-100,000 ppm·m
Accuracy ±20%@ Standard reflectivesurface
Response Time(T90) <0.1s
Display Type ColorLCD
EnvironmentalParameters
·OperatingTemperature -10-50℃
·Storage Temperature -40-60℃
·Operating Humidity ≤98%
·Operating Pressure 80kPa-116kPa
Power Specifications
·Endurance Normaloperation>10h Full-load operation>4h (with continuous audibleandvisualalarm)
·ChargingMethod Type-Cdirectcharging
·Battery Built-inLithiumManganateBattery
Lasersafetyclassification
·DetectionBeam CLASSI
·Alignmentbeam CLASSIIR
MechanicalConstruction
·Shell material Aluminum alloy
·Ingress protection IP67
·Weight 200g
EquipmentFunctions
Non-ContactLaserMethaneLeakDetection LeakSourceLocation&RealTimeAlarm Tri-modeAlarms(Sound/Light/Vibration) Dark Area Illumination Removable&Replaceable Battery
AreasofApplication
ResidentialGasSafety Inspection
·Detection inconfined dark spaces (cabinets,under stoves)
·Keypointchecks:gasmeters,alves,oes
Low-LightEnvironmentPatrol
·Urbanundergroundutility tunnels,deeppipeline&valvepits
·Unlit basements,corridors,and equipment room corners
End-PointPipeline Screening
·Detectionat hard-to-reach elevated &wall-mounted pipes
·Quick screeningof regulatorsand valvepitsinresidential areas
Industrial&CommercialConfinedSpaces
·Leakdetectionincramped equipmentlayers&flange joints
·Inspectionofhiddenpipelines&deadcornersincommercialkitchens
Certifications
ExplosionProtection ·China Ex ·ATEX -ExibIICT4Gb -ExII2GExiaIICT4Ga
Open Path Gas Detection
BA8 Portable Gas Detector BA8
ApplicationFeatures
Cost Innovation Solutions
·Optimized laser detection with premium-grade performance ·TDLAS enables permanent calibration-free operation
Intrinsic Safety System
* Full-processExib ICT4Gb certification * * False alarm immunity for vapor/chemical interference
Ultra-Portable Design
* Ergonomic structure for continuous wearable use * Multi-scenario deployment via pocket/belt carry
ProactiveAlertSystem
·Early-stage methane detection with pre-threshold alerts ·Tri-mode alarms (sound/light/vibration) trigger instant response
Specification
EquipmentFunctions
SamplingMethod MeasuringRange Accuracy
Resolution
Response Time(T90)
Display Type
EnvironmentalParameters
·Operating Temperature
·Storage Temperature
·Operating Humidity
·Operating Pressure
PowerSpecifications
·Endurance
·ChargingMethod
·Internal Battery
MechanicalConstruction
·ShellMaterial
·IngressProtection
·Weight
Passive Diffusion
0-100%LEL
0-60%LEL:±3%F·S
60-100%LEL:±5%F·S
1%LEL
≤25s
SegmentFSTN
-25-55C -40-60℃ ≤98% 80kPa-116kPa
≥10h Docking Charger|Cabinet Charger Built-in Lithium ManganateBattery
PC+TPE
IP65
200g
LaserMethane Detection
TemperatureandPressureDetection
Tri-modeAlarms(Sound/Light/Vibration)
Auto-Logging Storage
AreasofApplication
IndustrialSafetyStandard
·Cost-effectiveworkforce-widedeployment
·All-daywearablefor petrochemical/metallurgical processes
Confined SpaceMonitoring
·Real-timegasdetectioninundergroundutilities/tanks
·DynamicinspectioninWWTPrestrictedareas
CriticalOperations
·Multi-point monitoring during equipment overhaul
·Instantdatacaptureforprocessanomalies
EmergencyResponse
·Lightweightfor multi-tool rescuecoordination
·Explosion-proof reliability in extremeconditions
Certifications
Explosion Protection ·ChinaEx ·ATEX -ExibICT4Gb -ExII2GExibICT4Gb
Portable Gas Detection
Portable Multi - Gas Detector BB9
ApplicationFeatures
Maintenance-FreeRevolution
* TDLAS enables permanent calibration-free operation · 1 0 + year core durability,zero consumables & sensor poisoning
Precision Across Scenarios
* Micro-leak detection with interference immunity ·Reliable performance in { H } _ { 2 } { S } / { C O } _ { 2 } environments
Industrial-Grade Adaptability
·IP65 rating with impact-resistant housing * Optional pump for directional sampling
Uninterrupted Operation
* One-hand control with instantLCD feedback ·10h continuous runtime via smart docking
Specification
| SamplingMethod | Passive Diffusion/Active Sampling ColorLCD |
| DisplayType | |
| EnvironmentalParameters | |
| ·OperatingTemperature | -25-55℃ |
| ·StorageTemperature | -40-60℃ |
| ·Operating Humidity | ≤98% |
| ·OperatingPressure | 80kPa-116kPa |
| PowerSpecifications | |
| ·Endurance | ≥10h |
| ·ChargingMethod | ChargingDock |
| ·Internal Battery | Built-inLithiumManganateBattery |
| MechanicalConstruction | |
| ·ShellMaterial | ABS+PC |
| ·IngressProtection | IP65 |
| ·Weight |
EquipmentFunctions
LaserMethaneDetection Electrochemical CarbonMonoxide Detection Optional PumpSuction Sampling Temperature and Air Pressure Display TripleWarning (Beep/Flash/Buzz) AreasofApplication
UrbanGasSafety Confined SpaceProtocol ActiveMiningMonitoring Storage&TransportEmergency
Certifications
ExplosionProtection ExplosionProtection ·China Ex ·ATEX ·China MiningSafety -ExibIMb -IM2ExibIMb -MA(Coal Mine)
| PartNumber | GB992B97001 | GB811B08003 |
| TargetGas | CH4&CO | CH4 |
| MeasuringRange | 0-10 %VOL(CH4) 0-1,000 ppm(CO) | 10-5,000ppm |
| Accuracy | 0.00-1.00 %VOL:±0.06%VOL(CH) 1.0-10.0 %VOL:True value±6% (CH4) 0-100ppm :±4ppm(CO) 100-500ppm:True value ±5%(CO) 500-1,000ppm:True value ±6%(CO) | 10-100ppm:±5ppm 100-5,000ppm: True value±5% |
| Resolution | 0.01%VOL(CH4)1ppm(CO) | lppm |
| Response Time |
Protable Gas Detection
SelectableGasesforDetection
| Laser | CH4 | NH3 |
| Infrared | CO2 | |
| Electrochemistry | H2S | CO |
Unit:mm
Coal Mine Laser Gas Detector GJJ100B-INTL
\boxed { / { \mathsf { C H } _ { 4 } } { \mathsf { L a s e r } } }
ApplicationFeatures
SafetyInterlock Cutoff
* Auto-shutdown on gas overload prevents ignition risks ·SPDT-integrated system meets mining Ex-protected standards
Blackout Resilience
·LiMnzO4 battery ensures 4-hour continuous monitoring * Online auto-charging synchronizes with equipment power systems
Industrial-GradeArchitecture
·304L Stainless Steel sealed construction (IP65 rated) * * Compact design for confined space installations
Smart Connectivity
·RS485/CAN/4-20mA multi-interface support * Real-time temp/pressure data enables smart ventilation or speed control
EquipmentFunctions
SamplingMethod MeasuringRange Accuracy
Resolution
Response Time(T90)
Display Type
AlarmSoundLevel
EnvironmentalParameters
·Operating Temperature
·StorageTemperature
·Operating Humidity
·Operating Pressure
Power Specifications
·Backup Power Runtime
·ChargingMethod
·Internal Battery
·Input Voltage
·Power Consumption
CommunicationSpecification
·Communication Interface
·Communication Protocol RelayCharacteristics ·Contact Form ·Power Cutoff Capability
Mechanical Construction
·ShellMaterial
·Ingress Protection
·Weight
Passive Diffusion
0-100%VOL
0.00-1.00%VOL:±0.05%VOL
1.0-100.0%VOL:Truevalue±5%
0.01%VOL
≤25s
7-segment LED
>80dB@1m
0-40C
-40-60℃
≤98%
80kPa-116kPa
>4h
Onlineautomaticcharging
Built-inLithiumManganateBattery
12-24VDC
<4.8W RS485(Default) (CAN/4-20mAoptional for 0-10%VOL range)/200-1KHz output for
0-4%VOL range.
ModbusRTU
SPDT
5A@DC30V5A@AC250V
10A@AC125V
304StainlessSteel
IP65
2.0kg
LaserMethaneDetection
Over-LimitAlarmandPower-offControl
BackupPowerOperation
AreasofApplication
MiningEquipmentSafety
·CH4monitoring&powerinterlockforshearers/roadheaders
·Haul truck/shuttle car operational safety
SmartVentilation
·CH4-adaptive speedcontrol forfanarrays
·Ventilation optimization in gasdrainage
Critical ZoneMonitoring
·Methane accumulation in sealed goafs/tunnels
·Explosiveatmosphere monitoring for key facilities
MineModernization
·Gasprotection retrofits forlegacy equipment
·Smartsafetynetworksdeployment
Certifications
Explosion Protection
·ChinaEx
-ExibIMb
Functional Safety
·China MiningSafety
-MA(CoalMine)&KA(Non-coalMine)
SelectableGasesforDetection
Fixed Gas Detection
| Laser | CH4 | Co | CO2 | H2S | C2H2 | O2 | HCL |
| Infrared | CO2 | C3H8 | CH3OH | ||||
| Electrochemistry | CO | O2 | H | HCL | H2S | ||
| Thermal catalysis | Hydrocarbons | ||||||
Mining Laser Methane Power Failure Device
DJJ100/127-INTL
ApplicationFeatures
Highly Integrated, Ultra-Compact
·Built-in power cut-off and battery,smallest in itsclass ·Solves space constraints,easy to deploy
LaserCore,Accurate&Maintenance-Free
·TDLAS laser tech,millisecond response,shock-resistant ·High precision,no false alarms,6-month calibration
RobustStructure,Durable
·Round stainless steel shell disperses impact force ·Explosion-proof IP68,withstands dust and water
Flexible Power,Wide Compatibility ·AC127V& DC24V versions fit various systems ·Wide voltage design,stable in fluctuating conditions
Specification
Sampling Method Passive Diffusion
MeasuringRange 0-100%VOL
Accuracy 0.00-1.00%VOL:±0.05%VOL 1.00-100.0%VOL:Truthvalue±5%
Resolution 0.01%VOL
Response Time (T90) ≤25s
Display Type 7-segment LED
AlarmSoundLevel >80dB @1m
EnvironmentalParameters
·Operating Temperature 0-40℃
·Storage Temperature -40-60℃
·OperatingHumidity ≤98%
·Operating Pressure 80kPa-116kPa
InterferenceImmunity
·Electrical FastTransient/Burst ±2kV
Immunity
·Surge (Impulse) Immunity ±2kV
Power Specifications
·Backup Power Runtime >4h
·ChargingMethod Onlineautomatic charging
·Internal Battery Built-in Lithium Manganate Battery
·Input Voltage AC85\~265V/12-24V
·Power Consumption <4.8W
Communication Specifications
·CommunicationInterface RS485(Default) (CAN/4-20mAoptional for0-10%VOL range)/200-1KHz output for 0-4%VOL range
·Communication Protocol ModbusRTU
RelayCharacteristics
·Contact Form SPDT
·Power CutoffCapability 1A@AC240V (Limit Value) 1A@AC125V 2A@DC120V (LimitValue)
2A@DC30V
Specification
Mechanical Construction ·Shell material 304Stainless Steel ·Ingress protection IP68 ·Weight 2.2kg
EquipmentFunctions
OnboardMethaneReal-TimeMonitoring Exceed-AlarmandPower-OffControl BackupPowerCapability RemoteParameterSettingviaController
AreasofApplication
FullyMechanizedMining/Face
·Installed on shearers/roadheaders for mobile monitoring
UndergroundAuxiliaryTransport
·Explosion-proofvehicles:tracklesstires,personnelcarriers
ContinuousMiningOperations
·Continuousminers,shuttlecarsunderheavyvibration
OtherOnboardEnvironments
·Pointspronetoimpact:conveyorhead,transfermachines
Certifications
Explosion Protection FunctionalSafety ·China Ex ·China MiningSafety -Ex mb[ibMb]IMb -MA(Coal Mine)& KA(Non-coal Mine)
Fixed Gas Detection
Coal Mine Portable Laser Gas Detector BA8
ApplicationFeatures
CostInnovation Solutions
·Laser detection with price-optimized performance matching premium industry standards
·6-month calibration breakthrough in coal mining (vs.7-15 days standard)
Ultra-Portable Design
·Lightweight structure enables all-position wearable use ·Fuss-free deployment for multi-scenario carry (pocket/belt)
Intrinsic SafetySystem
·Full-process Ex ib IMb certification for mobile inspections ·Mist/dust false alarm immunity through anti-interference algorithms
Proactive AlertSystem
·Early-stage methane detection with pre-threshold alerts ·Triple-mode (sound/light/vibration) alarms ensure instant on-site response
Specification
Sampling Method Passive Diffusion
MeasuringRange 0-10%VOL
Accuracy 0.00-1.00%VOL:±0.06%VOL 1.0-10.0%VOL:Truevalue±6%
Resolution 0.01%VOL
Response Time (T90) ≤25s
DisplayType SegmentFSTN
EnvironmentalParameters
·Operating Temperature 0-40℃
·Storage Temperature -40-60℃C
·Operating Humidity ≤98%
·OperatingPressure 80kPa-116kPa
Power Specifications
·Endurance ≥10h
·ChargingMethod DockingCharger|CabinetCharger
·Internal Battery Built-inLithiumManganateBattery
Mechanical Construction
·ShellMaterial PC+TPE
·IngressProtection IP65
·Weight 178g
EquipmentFunctions
LaserMethaneDetection Temperature and Air Pressure Display TripleWarning(Beep/Flash/Buzz) Auto-Logging Storage
AreasofApplication
Universal SafetyGear
·Cost-effective deployment across workforce
·Unobtrusive wearing for full-processoperations
MobileMonitoringGrid
·Batchdeployment createsgasconcentration mapping
·Rapidchecksathigh-riskzones
TemporaryOperations
·Multi-point monitoringduringmaintenance
·Dynamic datacollection for ventilation tuning
EmergencyReadiness
·Lightweightformulti-tool rescueoperations
·Impact-resistantfordisaster environments
Certifications
Functional Safety ·ChinaMiningSafety -MA(Coal Mine)
ExplosionProtection
·China Ex
-ExibIMb
·ATEX
-IM2ExibIMb
Portable Gas Detection
ProductDimensions
Unit:mm
Detector Intelligent Charging Cabinet CLF-50WG-INTL
ApplicationFeatures
IntelligentManagement,Cost&Efficiency
·Smart issue/return,cyclic use,no idle instruments ·Boosts efficiency,reduces manpower
Full-ProcessData Traceability
·Logs instrument charging& personnel info,generates reports ·Issue,return, chargingall traceable
Multi-SafetyProtection,Unattended
·Real-time charging monitoring,over-current protection,fault alarm ·Supports unmanned operation,reliable operation
DigitalAdaptability&SystemIntegration
* Interfaceswith digital mine platforms,open API ·Enables automated,info-based, intelligent equipment management
EquipmentFunctions
·High-CapacityClusterManagement
Asinglecabinetaccommodates50detectors,supportswired/wireless networking,andeablesutomatedcharging,dispatch,andrurn. ·IntelligentFaultLockout
Automaticallycheckslasersensors,firmware,andbatterystatus. Locksfaultyunitstoensureonly 1oo%compliant instrumentsare issued.
·Multi-LevelSafetyProtection
Industrial-gradecircuitdesignwithshort-circuit,over-current,and over-voltageprotection.Real-timechargingmonitoringensuressafe operation.
·ConvenientOperation&Management
Returneddetectorscanbeplugged intoanyfreeslot(NFCauto-recognition).Iris+facial recognitionenablesfast,secureaccess.
·GranularPermissionControl
Supportssuper/regularadminroleswithclearpermissionlevels, ensuring assigned personnel responsibility.
·FulllifecycleDataManagement
Automaticallyogsuage,ssue,ndreturnhistory.upportsel import/export,print,and inspection-datealertsforfull traceability.
Specification
SingleCabinetCapacity 50Units
InputVoltage AC220V
InputCurrent <4A (Per Cabinet)
Charging Protection Response Time 5ms
ChargingMode Theterminalchargingmanagementfeatures intelligentconstantvoltageandconstant currentchargingmodes.
Unit Display Shows Photo Employee Information ChargingPowerLevel Charging Voltage Charging Current CabinetDoor Status Instrument Charging Status, etc
External Dimensions
·Per Cabinet External Dimensions 3100(Length)\*300(Width)\*2070(Height)mm
·Internal CavityDimensions 300(Depth)\*240(Width)\*180(Height))mm
EnvironmentalParameters
·Operating Temperature -5-40°℃
·OperatingHumidity <95%RH
·Storage Temperature -20-60℃
·Storage Humidity <90%RH
EnvironmentalParameters
·Weight 400kg
Coal Mine Portable Laser Gas Detector BC8
ApplicationFeatures
Dual-Laser Detection Technology
·Cross-interference-free simultaneous { C H } _ { 4 } / { C O } _ { 2 } monitoring ·Enhanced molecular selectivity eliminates catalytic sensor false alarms
Full-Scenario Adaptation
·Ex-certified explosion-proof construction for hazardous zones ·316L stainless steel core components resist coal dust and corrosion
IntelligentSupportSystems
·Temperature-pressure compensation neutralizes environmental interference ·Real-time sensor health diagnostics with degradation alerts
Digital InspectionIntegration
·RFID-enabled automated gas logging with inspection point
geolocation
·Bluetooth/WiFi real-time data streaming to central monitoring systems
Specification
SamplingMethod Passive Diffusion
MeasuringRange 0-10%VOL (Customizable0-100%VOL) (CH4) 0-5.00%VOL (CO2)
Accuracy CH4 0.00-1.00%VOL:±0.05%VOL 1.00-4.00%VOL:±0.10%VOL 4.00-7.00%VOL:±0.20%VOL 7.00-10.0%VOL:±0.30%VOL CO2 0.00-0.50%VOL:±0.10%VOL 0.50-5.00%VOL:± (0.05+Truevalue5%)
Resolution 0.01%VOL
Response Time (T90) ≤25s
Display Type Monochrome OLED
EnvironmentalParameters
·Operating Temperature 0-40℃
·Storage Temperature -40-60℃
·Operating Humidity ≤98%
·Operating Pressure 80kPa-116kPa
PowerSpecifications
·Endurance ≥10h
·ChargingMethod Charging Dock
·Internal Battery Built-inLithiumManganateBattery
MechanicalConstruction
·ShellMaterial ABS+PC
·Ingress Protection IP65
·Weight 423g
EquipmentFunctions
LaserMethane&CarbonDioxideDetection Temperatureand Air Pressure Display Bluetooth&WiFiCommunication RFIDInspection Check-in TripleWarning(Beep/Flash/Buzz)
AreasofApplication
Critical ZoneMonitoring
·Dual-gas dynamics in working face apex zones
·ConcurrentCO/CH4 monitoringin returnairways
SealedSpaceSafety
·Dual-riskcontrol duringgoaf seal removal
·CH4-CO2interaction tracking inabandoned workings
Post-DisasterEvaluation
·Post-firegasinterferenceresolution
·Dual-gascomplianceassessmentinblast zones
EmergencyManagement
·Evacuationpathgasmatrixmodeling
·Safety-tieredalternativeroutemanagement
Certifications
Explosion Protection ExplosionProtection ·China Ex ·ChinaMiningSafety -ExibIMb -MA(Coal Mine)
Protable Gas Detection
Coal Mine Laser Methane Remote Sensing Detector XB8
ApplicationFeatures
Non-Invasive Laser Sensing
0 * 0 . 5 { - } 3 0 { m } open-path detection for goaf/blind lane monitoring ·Class IIIR green laser visualizes gas plumes in low-light conditions
Intrinsic SafetyDesign
·ExiaIMa certification for explosive methane atmospheres ·Ergonomic mobile configuration suits rescue operations
InstantResponse&HarshEnvironmentResilience Dual-Mode PowerManagement
·Subsecond T90 response time captures methane spikes ·IP65 rating with optical path compensation for high humidity /dust
·Full load alarm _ { 1 > 3 } hours,automatic mode exceeds 5 hours, manual mode has longer battery life ·Dedicated charging dock for fast energy replenishment
Specification
OpenPath
30m
30m
0-100,000 ppm·m
Truevalue±20%@Standard reflective surface
<1s
ColorLCD
Sampling Method
PathLengths
Measuring Range
MeasuringRange
Accuracy
Response Time (T90)
Display Type
EnvironmentalParameters
·Operating Temperature
·Storage Temperature
·Operating Humidity
·Operating Pressure
PowerSpecifications
·Endurance
-10-50℃ -40-60°℃ ≤98% 80kPa-116kPa
Automaticmode>5h Full load operation>3h (Continuoussoundandlightalarm) Built-inLithium ManganateBattery
·ChargingMethod ChargingDock
·Internal Battery
LaserSafetyClassification
·Detection Beam CLASSI
·AlignmentBeam CLASSIIIR
·RangingBeam CLASSII
Mechanical Construction
·ShellMaterial ABS+PC
·Ingress Protection IP65
·Weight 420g
EquipmentFunctions
HandheldMethaneLeakLocator LaserRanging TripleWarning(Beep/Flash/Buzz)
AreasofApplication
MiningFaceGasMonitoring
·Real-timeCH4 fluctuation trackingat shearer drums/roadheader cutterheads
·Mobile inspectionalongconveyors/rail trackstopinpoint gasleakage
SealedZoneAccessControl
·Non-contactdetectionthroughcracks/ventsinsealedroadwaydoors
·Pre-entryremotescanningformethanehotspotsinabandonedfaces
VentilationSystemValidation
·CH4gradientanalysisacrossairlockdoors/aircrossings
·Multi-point laser scanningidentifies stagnant gas zones
Post-DisasterAssessment
·Remotegasdispersionmappingafteroutbursts/explosions
·Dynamic concentrationanalysisfor safe rescueroute planning
EquipmentMaintenanceSafety
·Non-contactmethanescreeningbefore liveelectricalmaintenance
·Continuousmonitoringduringweldingtoprevent ignition
Certifications
Explosion Protection ·ChinaMiningSafety -MA(Coal Mine)
ExplosionProtection
·China Ex
-ExiaIMa
·ATEX
-ExIM2ExiaIMa
| Laser | CH4 | NH3 | C2H2 | Co | CO2 | HCL | O2 |
Portable Gas Detection
ProductDimensions
Gas Sampling Pump TX1000-INTL|Telescoping version
Portable Gas Detection
Specification
Sampling Pump Flow >550mL/min
EnvironmentalParameters
·OperatingTemperature 0-40C(Mining) -10-40℃(Industrial)
·Storage Temperature -20-60℃
·Operating Humidity ≤98%
·Operating Pressure 80kPa-116kPa
MechanicalConstruction
·ShellMaterial ABS
·Weight 240g
Certifications
ExplosionProtection ·ChinaEx -Ex ibIMb(Mining) -ExibIICT6Gb(Industrial)
ProductDimensions
Gas Sampling Pump
TX1000-INTL|Wanxiangstyle
Portable Gas Detection
Specification
ProductDimensions
| SamplingPumpFlow >550mL/min EnvironmentalParameters |
Certifications
ExplosionProtection ·China Ex -ExibIICT6Gb
Optical Reflector TX3000-INTL
Open Path Gas Detection
Specification
Reflectivesurfacematerial
MechanicalConstruction
·Framematerial
·Size
·Weight
Special PVC
Aluminium Alloy
500mm\*500mm
(1000mm\*1000mmPremium)
>2.1kg
Calibration Gas Box TX4000-INTL
Open Path Gas Detection
Specification
ProductDimensions
DetectGas Methane (customizable for other gases)
measurementrange 0-9999ppm ·m (other ranges can be customized)
powersupplyvoltage 5VDC
MechanicalConstruction
·Shell material Acrylic,Quartz
·Weight 5kg
Website:www.dltxcgeur.com www.dltxcg.com
E-mail:chinatx@dltxcg.com
Tel:400-993-5599
Address:No.181-1LiaoheWestRoad,DalianDDA,Liaoning,China116600